PR NO. 19-03-1445 (2 units CTG Machine. For use in Cebu Provincial Hospital – Danao City (PHO).

Republic of the Philippines
Province of Cebu
BIDS and AWARDS COMMITTEE
Cebu Capitol, Cebu City
MODE OF PROCUREMENT : NEGOTIATED 53.9
Control No. 19-1080 Dated : March 20, 2019
Note: Please state the fullname of the establishment P. R. No. 19-03-1445 Dated : March 19, 2019
        as appearing in the OFFICIAL RECEIPTS. O.R. No. 100-19-03-1382 Dated :
ABC: P570,000.00
Gentlemen:
            Please quote your prices on the following listed articles which the Province of Cebu desires  to  buy  if
to the government. For clarification & inquiry call Telefax Nos. 253-7160 or 888-2328 local 1228 – 1229 or email us
at bacgscapitol@gmail.com.
♥ Prices quoted should be VAT inclusive and subject to withholding tax.
♥ PhilGEPS Registration Number: ______________________
♥ Terms of payment: _________________________
♥ Delivery Date: 30CD     BIDS and AWARDS COMMITTEE
♥ Deadline of quotation: _______________________
♥ TIN No.: ______________________________________________________________ (Sgd)
♥ Place of Delivery: @ PGSO-Warehouse ATTY. MARK C. TOLENTINO
♥ Note: Must have a satellite office/service center in Cebu (for supplier outside Cebu).                     BAC Chairman
♥ Please submit  Certified True Copy of Business/Mayor’s Permit.
Item Quantity Unit                             Articles and Description Brand Offer Unit cost Total Price
1 2 Units CTG Machine, Heavy Duty, Twin FHR, w/ Stand
Performance Specifications:
 * Display: 10.2 inch, color TFT -LCD
 * Resolution: 800 x 480
 * Recorder: 1/2/3 cm/min. real-time
PRINTING SPEED:
 * Fast Print Speed (Stored Traces): up to 25mm/sec.
 * Paper: 150/152mm, Z-Fold, Thermosensitive
 * American/International Standard
ULTRASOUND:
 * Technique: Ultrasound Pulse Doppler w/ Autocorrelation
 * Pulse Repetition Rate: 2 Khz.       * Accuracy: +2 bprm
 * Ultrasound Frequency: 1.OMHz +1O%
 * FHR Range: 50bpm -240bpm      * Resolution: 1bpm
TOCO:
 * Range: 0-100 Relative (%)     * Resolution: 1 Count
 * Zero Mode: Auto Manual      * Non-Linear Error: 10%
IUP:
 * Pressure Range: 0-100mmHg      * Resolution: 1%
 * Zero Mode: Auto Manual      * Non-Linear Error: +1mmHg
 * Auto Fetal Movement (AFM)
TECHNIQUE: Pulsed Doppler Ultraound
 * Range: 0-100 (%)        * Resolution: 1%
Marking: Manual Fetal Movement Mark
Battery: 14.8V Rechargeable Lithium -Ion
Continual Working Time: 2-4 Hours
Signal Interface: DB9 Network Interface, RJ45 Interface
With ONSITE Demonstration
PURPOSE: ***For use in Cebu Provincial Hospital – Danao City (PHO).***
Canvassed by ____________________
    Signature of bidder or his/her representative
                    over printed Name
PLEASE LABEL YOUR ENVELOPE. Sign your Quotation and State the brand of the Articles quoted.
TO DOWNLOAD THE FILE, PLEASE CLICK:
Copy of 19-03-1445